Halogen Hotspot 12V - 50W, for bathrooms, IP54 D90x30

Model: 78R6508
  • Price: 35.55 $
  • Shipping costs: 8.02 $
    • Handling Time: 5 days
    • Object location: Map

Discover our products visiting our website www.tronitel.com
faretto alogeno vendita on line - on line halogen hotspot buy

Ip54: can be used in bathrooms and wet environments;
Construction material(s): structure in alluminium, glass diffuser;
Available finishings: Alluminium;
Bulbs:  1 x GU5.3 Max  50w ;
Exavalent chromium free (It is lethal...);
Rohs certified (toxic substances free);
CE Certified (European saftey standard comply)
Electrical material certified and marked by the most important European electrotechnical safety institutes.

 



Bulbs not included, click here to buy.

 

This spot requires a transformer (not included), click here to buy one:

transformers

How to choose a transformer.

1) Choose a transformer which power is greater than or equal to the sum of all spots power.
2) It may be necessary to use more transformers to reach power needed

Example 1.

1) You have to install two 20W spots: total power applied is 20Wx2=40W

2) You can use a transformer with a power range between 10W up to 60W (infact total power of the spots is less than 60W)

Example 2.
1)
You have to install five20W spots. total power applied is 20Wx5=100W.
2) If the power range of  your transformers is between
10W up to 60W it's clear that just one transformer is not enough to feed 5 spots. So you need at least 2 transformers. Link three spots (3x20W=60W) to one transformer and the other two (2x20W=40W) to the second transformer.

 

How to install a low tension spot using a transformer.

WARNING: RISK OF DEATH!  BEFORE PROCEDING SWITCH OFF ELECTRICITY AT THE MAIN!

collegamento di un 

    faretto a bassa tensione

A transformer is a device that transforms main voltage (230-240V) incoming in its primary circuit into low voltage (12V) outgoing from its secondary circuit.

Connect spot cables with the secondary circuit of the transformer (one cable for each clamp of the secondary circuit). Switch off alectricity at the main, then connect main cables with the primary circuit of the transformer: Live (red cable) with live; neutral (blue) with neutral. Never invert polarity or short circuit.

transformers

Warning: an electric shock may be fatal, if any doubt please contact a qualified electrician.